DRM-3000 Monitor

The DRM-3000 Monitor is the latest innovative instrument designed to provide the best possible user experience in Area Monitoring today. The DRM-3000 supports three external detectors and one internal detector, with automatic identification from a wide range of external detectors up to 100 meters distant to the Monitor

DRM-1 Data Radiation Monitor

The DRM-1 is a GM tube-based wide range Area Monitor. It has been designed specifically to be used as a fixed monitor in varying dose rate fields using two very sensitive, auto switching GM tubes.

The DRM’s detector features a linear response from 10uR/h to 1000R/h (0.1μSv/h to 10Sv/h).

DRM-1D Data Radiation Monitor

The Data Rate Monitor (DRM-1D) is a sensitive CsI(Tl) Scintillator coupled to PMT dose rate meter, and is a state-of-the-art microprocessor-based instrument, combined with the telemetry using the WRM2900 MHz or 2.4 GHZ FHSS radio.

The DRM-1D is designed for highly stable and accurate measurements of rate from gamma radiation. The DRM Measuring range is from 0.01 μSv/h to 100 μSv/h (0.001 mR/h to 10 mR/h )

DRM-2 Data Radiation Monitor

The DRM-2 is a GM tube-based wide range Area Monitor.  It has been designed specifically to be used as a fixed monitor in varying dose rate fields using two very sensitive, auto switching GM tubes. The DRM’s detector features a linear response from 10uR/h to 1000R/h  (0.1µSv/h to 10Sv/h).

DRM-2D Data Radiation Monitor

The Data Rate Monitor (DRM-2), a sensitive CsI(T1) Scintilator coupled to PMT dose rate meter, is a state-of-the-art micro-processor based instrument, combined with the telemetry using the WRM2 900 MHz or 2.4 GHZ FHSS radio.

DRM-2E Data Radiation Monitor

The DRM-2E is a GM tube-based wide range Area Monitor. It has been designed specifically to be used as a fixed monitor in varying dose rate fields where the detector is mounted at a distance from the Monitor

The DRM’s detector features a display range from 0.1μSv/h to 10Sv/h (10 uR/h to 1000 R/h).

DRM-2N Data Radiation Monitoring System

The DRM-2N is a GM tube-based wide range Area Monitoring system. It has been designed specifically to be used as a fixed monitor in varying dose rate fields using two very sensitive, auto switching GM tubes. The DRM’s detector features a linear response from 0.1μSv/h to 10Sv/h (10uR/h to 1000R/h).

AMP 300 Area Monitoring Probe

The AMP-300 Area Monitor Probe, is a Si-Diode based, waterproof rate meter. It has been designed specifically to be used in extremely high dose rate fields from 1 mGy/h to 300 Gy/h with a lifetime of 5,000 Gy.

AMP 50 Area Monitor

The AMP-50 is a GM tube-based low range Area Monitor.  It has been designed specifically to be used in low dose rate fields using a very sensitive GM tube

AMP 100 Area Monitor

The AMP-100 Area Monitor Probe is a GM tube based rate meter. It is a state-of-the-art microprocessor-based instrument, designed for highly stable and accurate measurements of dose rate and integrated dose rate gamma radiation.

The AMP-100 covers a measuring range of 10 uSv/hr to 10 Sv/hr

AMP 200 Area Monitor

The AMP-200, or Area Monitor Probe, is a GM tube-based rate meter. It has been designed specifically to be used in high dose rate fields. The AMP-200’s detector features linear response

from 10 mSv/h to 150 Sv/h .

Model 375 Gamma Area Monitors

A choice of several area monitor configurations that are all based upon the versatile and very affordable Model 375 Digital Controller. Each of the area monitors presented in this section can be equipped with optional remote annunciators, camera and be networked together for central data acquisition and alarming.

Model 375/2 Area Monitor

SPECIFICATIONS:

INDICATED USE: General purpose area monitor

DETECTION RANGE:  1 uSv/hr to 10 mSv/hr.

DETECTOR TYPE: Internally mounted energy compensated GM

SIZE: 18.7 H x 24.6 W x 6.4 cm D

WEIGHT: 2.3 kg 

Model 375/4 Area Monitor

SPECIFICATIONS:

INDICATED USE: General purpose area monitor

DETECTION RANGE: 10 uSv/hr to 100 mSv/hr.

DETECTOR TYPE: Internally mounted energy compensated GM

SIZE: 18.7 H x 24.6 W x 6.4 cm D

WEIGHT: 2.3 kg

Model 375-9 Area Monitor

SPECIFICATIONS:

INDICATED USE: Areas requiring fast response to pulsed fields

DETECTION RANGE: Any 5 decade range between 1 uSv/hr to 10 Sv/hr.

DETECTOR TYPE: External ion chambers, Model 45-9, user mounted

SIZE: 18.7 x 24.6 x 6.4 cm excluding detectors

WEIGHT:  2.3 kg excluding detectors

Model 375-10 Area Monitor

SPECIFICATIONS:

INDICATED USE: High sensitivity, low energy gamma areas

DETECTION RANGE: 0.1 uSv/hr to 20 uSv/hr.

DETECTOR TYPE: Internally mounted 2″ x 2″ Nal(TI) scintillator.

A removable lead-shield surrounds the detector providing greater resistance to alarm on low-energy fields

SIZE: 26.2 x 24.6 x 8.4 cm

WEIGHT: 4.2 kg

CONNECTION: 10Base-T Ethernet included

Model 375-20, Waste Monitor

  • 2 x 2 inch NaI(Tl) detectors
  • 1670 cps/µSv/hr sensitivity
  • Fixed alarm (sigma type optional)
  • Model 375 type controller

Model 375-30, Landfill/Transfer Station Monitor

  • 3 x 1 inch lead shielded Nai(Tl) detectors
  • 4000 cps/µSv/hr sensitivity
  • Fixed alarm (sigma optional)
  • Model 375 type controller

Model 375-336, Waste Release Monitor

  • wall-mounted 168 in3 plastic scintillator detectors
  • xxx cps/µSv/hr sensitivity
  • Sigma & sum alarms

Model 375-1000v, Gateway Monitor

  • 480 in3 plastic scintillator Detectors
  • 40,000 cps/µSv/hr sensitivity
  • Sigma & sum alarms
  • Model 375 type controller